The zimmer m l taper hip prosthesis is available in 14 body sizes 4 0mm through 22 5mm.
Ceramic femoral head prosthesis.
A combination of a ceramic acetabular liner with a 36 mm ceramic femoral head was chosen.
If ceramic is used in the femoral head component of the prosthesis major prosthetic failure can occur with very subtle radiological abnormality or even normal radiographical appearance.
The stem portion of the femoral stem is inserted into the femur.
The cloud sign amorphous densities in the peri prosthetic tissues and the bubble sign hyper dense rounded images with a higher contour.
Only uncemented devices were evaluated.
Non traumatic fracture of a fourth generation ceramic femoral head.
During the procedure a low femoral neck cut resulted in a fracture of the greater trochanter which was subsequently fixed with two partially threaded screws.
The femoral templates show the neck length and offset for each of the head neck combinations 3 5 to 10 5mm.
Acetabular head revision the sleeved ceramic femoral head can be used on either a new pristine stem or a previously implanted stem.
The primary outcome was all cause revision n 28 772 and the secondary outcome was dislocation within 1 year n 19 623.
Stryker is a leader in the worldwide market of hip replacement products.
All of these parts tend to be manufactured by the same company and implanted as a set.
Femoral heads can be ceramic or metal.
A cementless total hip arthroplasty prosthesis was implanted through a transgluteal approach.
Femoral component include determining the anticipated size of the implant to be inserted and the location of the femoral neck osteotomy.
If the ceramic femoral head is being used with a previously implanted stem use the goldberg1 scale to determine if the condition of the trunnion is tolerable or intolerable.
The material of the femoral head metal ceramic was crossed with head size 32 32 36 36 mm yielding eight device groupings.
Stryker says this ceramic acetabular part demonstrated significantly lower wear versus conventional plastic on metal or metal on metal joint systems in the laboratory.
The stryker v40 femoral head is causing problems for thousands of hip implant.
Femoral head ball.
Ceramic components are said to be advanced when it comes to extending the lifetime of the implant.
As a result clinical findings become much more important.
A ceramic femoral head and a ceramic lining ceramic on ceramic in addition during june 2011 the fda approved a new ceramic on metal system.